Do you need help?
    Call us and we will be happy to help you!+49 7520 9661-0
    Call our service hotline and we will be happy to help you.+49 7520 9661-150
    Netzersatzanlagen von TEDOM SCHNELL

    Gas Backup Power Systems


    One-stop shop for all-in-one solutions

    One-stop shop for all-in-one solutions

    Backup Power Systems

    30 — 670 kVA (PRP)

    Gas Backup Power Systems

    • Easy fuel handling
    • Few constraints due to environmental requirements
    • Low exhaust emissions
    • No fuel conditioning needed
    • Small footprint from eliminating the diesel storage tank
    • No need to handle diesel exhaust fluid
    • Available in an open design or equipped with an acoustic or weather enclosure

    Gas Backup Power Systems 30 – 670 kVA (PRP)

    Technical Data

    TypePRP¹ in kVALTP² in kVANatural gasLiquefied petroleum gas (propane)Open design: dimensions, weightAcoustic and weather enclosure: dimensions, weight
    GGW 35 G31351,980 x 1,000 x 1,130 mm; 800kg3,085 x 1,135 x 1,690 mm; 1,360kg
    GGW 50 G45501,980 x 1,000 x 1,130 mm; 850kg3,085 x 1,135 x 1,690 mm; 1,360kg
    GGW 70 G63702,400 x 1,000 x 1,900 mm; 900 kg3,085 x 1,135 x 1,690 mm; 1,360kg
    GGW 200 G180200x3,540 x 1,500 x 1,870 mm; 2,750 kg4,410 x 1,540 x 2,250 mm; 3,450 kg
    GGW 300 G270300x3,540 x 1,500 x 1,870 mm; 2,800 kg4,410 x 1,540 x 2,250 mm; 3,500 kg
    GGW 400 G360400x3,800 x 1,670 x 1,870 mm; 3,940 kg4,700 x 1,670 x 2,190 mm; 4,850 kg
    GGW 500 G450500x3,800 x 1,670 x 2,040 mm; 4,650 kg4,700 x 1,670 x 2,190 mm; 5,975 kg
    GGW 625 G560625x4,375 x 2,115 x 2,465 mm; 7,350 kg6,536x 2,140 x 2,810 mm; 9,750 kg
    GGW 750 G670750x4,375 x 2,115 x 2,465 mm; 7,550 kg6,536 x 2,140 x 2,810 mm; 9,950 kg

    PRP: prime running power
    Prime running power is the maximum power that a generator set has during a variable power sequence for an unlimited number of operating hours at stated ambient conditions between the required maintenance intervals. 

    ✓ = Available  |  x = Not available

    Errors excepted. Subject to modifications. | Version: September 2021

    2 LTP: limited-time running power
    Limited-time running power is the maximum power that a generator set can deliver for up to 500 hours per year at stated ambient conditions between the maintenance intervals. Only 300 hours can be continuous running. 

     

    3 – 5.000 kVA (PRP)

    Diesel Backup Power Systems

    • Needs-based, customer-centric energy strategies
    • Partial or complete solutions integrated in your energy systems
    • All-in-one solutions customized for you
    • Proven industrial engines
    • Excellent performance under load / when connecting additional loads

    9 – 100 kVA (PRP)

    PTO Generators

    • Mobile power source
    • Certified under the regulations of the German Agricultural Liability Insurance Association
    • Driven by a tractor or other prime mover with a three-point hitch and a power take-off shaft
    Would you like a consultation?
    We would be happy to help.